|
Fluke designs and manufactures calibration instruments in a wide variety of product categories.
Besides their use for calibration, these instruments have several characteristics in common as you will find below.
 |
5320A Multifunction Electrical Tester Calibrator
Verify and calibrate electrical test tools with a single instrument
The Fluke 5320A Multifunction Electrical Tester Calibrator is an accurate, flexible instrument
that allows you to calibrate many different types and models of electrical testers efficiently
and effectively.
The 5320A replaces resistors, decade boxes, and other custom calibration solutions with a
single instrument. It features precision high voltage, high current resistors to give you
better test uncertainty ratios (TURs).
Using one multifunction instrument instead of many allows you to free up valuable bench
space and simplify the processes you use for calibrating electrical testers.
You will find the 5320A calibrator remarkably easy to use. A big, bright, full-color screen
displays values clearly, and shows which terminals are active in an easy-to-comprehend graphic
format. An illustrated Help Guide is built into the instrument to provide additional assistance
if you need it.
For even greater efficiency, the 5320A can be automated with MET/ CAL® Plus Calibration
Management Software. MET/CAL Plus software has become the industry standard for automating the
calibration process and managing the inventory of your cal lab. MET/CAL Plus is a complete,
scalable and affordable solution.
LAN, GPIB and RS-232 interfaces on the 5320A provide convenient, industry standard connectivity
|
 |
5500A Multi-Product Calibrator
Calibration solutions that match your workload and budget
The 5500A is a revolutionary product that addresses a wide cross-section of your electrical
calibration work load. It sources direct voltage and current, alternating voltage and current
with multiple waveforms and harmonics, two simultaneous voltage outputs or voltage and current,
and simulates power with phase control, resistance, capacitance, thermocouples and RTDs. The
5500A's Oscilloscope Calibration options provide level sine wave, fast edge, time mark and
amplitude signals for calibration of oscilloscopes up to 600 MHz.
The 5500A was designed to cover a very wide range of medium accuracy electrical measurement devices including:
- Handheld and bench multimeters
- Oscilloscopes and ScopeMeter® Test Tools
- Wattmeters
- Analog volt/ohm/amp/watt instruments
- Electronic thermometers
- Data loggers
- Strip chart recorders
- XY Recorders
- Power harmonics analyzers
- Process calibrators
- Current clamps
- And related instruments
|
 |
5500A Multi-Product Calibrator Workstation
Wide workload coverage and software automation in a turnkey solution
The 5500A calibrator is the original 11-calibrators-in-one instrument, addressing a wide portion
of your electronic calibration workload. MET/CAL LITE automates the 5500A, providing the power of
MET/CAL Plus software in a lower cost version designed for use with selected Fluke calibrators
(MET/CAL LITE is available only as part of selected Fluke workstation products).
Together, these products provide a turnkey solution for a beginning cal lab, or an existing lab
that wants to expand into electrical calibration.
|
 |
5520A High Performance Multi-Product Calibrators
Calibration solutions that match your workload and budget
The Fluke 5520A builds on the 5500A's capabilities, extending its workload coverage even
further. Its improved accuracy, expanded ranges, and capability to calibrate 5 1/2 and 6 1/2
digit multimeters can cover virtually all your high-performance workload, including:
- Handheld and bench meters (analog and digital) up to 6 1/2 digits
- Thermocouple and RTD thermometers
- Process calibrators
- Data loggers
- Strip and chart recorders
- Watt meters
- Power harmonics analyzers
- Current clamps and clamp meters
- Analog or digital handheld and bench oscilloscopes (with options)
- Panel meters
- Graphical multimeters
- Power meters, disturbance analyzers, power quality monitors, recorders and other power quality related equipment (with option)
|
 |
5520A Multi-Product Calibrator Workstation
A turnkey solution for calibrating today’s advanced 6.5 digit bench DMMs
The Fluke 8845A/8846A Digital Multimeters have the precision and versatility to handle demanding
measurements. These 6.5 digit multimeters feature a basic V dc accuracy of up to 0.0024 %, which
can pose a challenge when the time comes to calibrate them.
Fluke offers a turnkey solution that can handle this job and more, with a winning combination of hardware and software:
- 5520A Multi-Product Calibrator This workhorse is really 11 calibrators in 1, including the ability
to calibrate frequency, capacitance, and temperature.
- 8508A Reference Multimeter Use the 8.5 digit multimeter to characterize the 5520A, for an improved
4:1 test uncertainty ratio for calibrating the 8845A/8846A.
- MET/CAL® LITE software MET/CAL LITE software delivers automated calibration that is easy, powerful,
and a great value. It includes all of the features of the world-leading MET/CAL® Plus software, in a
lower cost version designed for use with the 5520A and 8508A.
- 8846A Digital Multimeter Our turnkey solution includes the workload!
Already own an 8508A multimeter? A workstation is available with just the 5520A calibrator, MET/CAL LITE, and the 8846A meter.
|
 |
5700A/5720A Multifunction Calibrators
Taking accuracy to a new level
The 5700A and 5720A are five-function calibrators designed to address the most demanding
electrical calibration workload. They source direct and alternating voltage and current and
resistance. A wideband voltage option extends overall ac bandwidth to 10 Hz to 30 MHz to cover
to RF voltmeters. Both are compatible with the 5725A, and 5205A/5215A amplifiers.
|
 |
5700A/EP Upgrade
Take your 5700A to a new level of performance
The 5700A/EP is an upgrade service that extends both the performance and service life of your
existing 5700A Multifunction Calibrator. Through the installation of new hardware and software,
your working 5700A, no matter how old, will be brought up to the performance equivalent of a
state-of-the-art 5720A, at half of the cost of a new calibrator. All work is performed at Fluke's
manufacturing facility in Everett, Washington, USA, with rigorous testing and verification performed
on the actual 5720A production line.
|
 |
5820A Oscilloscope Calibrator
Dedicated oscilloscope calibration that is flexible, powerful and affordable
The powerful 5820A Oscilloscope Calibrator is a complete, yet flexible solution for oscilloscope
calibration. It calibrates virtually all your digital and analog oscilloscopes quickly, easily and
affordably. Even in its basic configuration, the 5820A provides tremendous versatility, allowing you
to meet the manufacturer's calibration requirements for oscilloscopes up to 600 MHz.
With its high bandwidth option, the 5820A's performance can be extended still further, to
oscilloscopes up to 2.1 GHz. And the 5820A's five-channel output option facilitates fast,
hand-free automated calibrations. Best of all, either option can be purchased with a new 5820A,
or added later as your needs change and grow.
Do you need to justify the expense of a new oscilloscope calibrator? Our Oscilloscope Calibrator
Return on Investment Calculator can help you estimate how long it will take to recover the costs
invested in a new calibrator. The calculator is an easy-to-use downloadable Excel file (55 KB).
|
 |
9100 Universal Calibration System
The world’s best value multi-product calibrator
If you're constantly being asked to calibrate more and more with less and less, Fluke's 9100
Calibration System is the answer you've been waiting for. Its exceptional performance in both the
analog and digital domain allows it to calibrate an extremely wide range of test and measurement
equipment - quickly, efficiently and to ISO 9000 requirements.
For the 9100, calibrating everything from handheld digital multimeters to high performance
digital-storage oscilloscopes is all part of a day's work.
Take advantage of the Model 9100's unique procedure mode, which guides operators step-by-step
through the entire calibration process, and you'll not only calibrate more with less - you'll do it faster.
The 9100 is a multifunction calibrator with a breadth and depth of outputs never before available from a
single calibration source. In addition to DC and AC voltage to 1050V, variable Resistance to 400MO and DC and
AC current to 20A (1000A via the optional current coils), the 9100 delivers continuously variable capacitance
values to 40mF and conductance values to 2.5 milliSiemens. It also generates digitally synthesized and phase-locked
sine, square, triangle, impulse and trapezoidal waveforms, variable amplitude pulses to 10 MHz, pulse widths to 2
seconds, and duty cycles between 0.05% and 99.95%.
Add one of the two oscilloscope calibration options and it generates all the waveforms required to calibrate
oscilloscopes up to 250 MHz or 600 MHz.
Fit the insulation/ continuity tester option and it synthesizes resistance values as high as 2GO at test voltages
up to 1000V. Fit the power meter option and it simultaneously generates variable phase angle voltages and currents
that allow you to calibrate power meters up to 1 MW or 1 MVAR.
No other multi-product calibrator gives you such wide workload coverage and versatility. Weighing in at only 41
lbs (18.5 kg), it's also the ideal solution to on-site calibration.
|
 |
9500B Oscilloscope Calibrator
The world's highest performance, fully automated, upgradeable oscilloscope calibration workstation
Oscilloscope calibration can be complex, time consuming and expensive. A significant amount of skilled
operator interaction and interpretation is often required to complete the job, and today’s multi-channel
instruments frequently mean that a great deal of lead switching is required. Even automated systems require
significant manual intervention to complete elements of the most simple calibration procedures. Worse still,
switching systems or multiplexers used to enable a degree of automation often contribute more errors and
aberrations than the instrument being calibrated.
To compound the problem, rapid developments in oscilloscope technology make it difficult to keep up with
performance trends without substantial re-investment on a regular basis. The Fluke 9500B Oscilloscope Calibration
Workstation breaks that paradigm. It means that the benefits of hands-free, fully-automated, accurate oscilloscope
calibration are readily available to everyone at a price and performance level that your needs and budget can
support, while ensuring that, through performance upgrades, future needs will be met when the time demands it.
9560 Active Head – for ultimate leveled sine performance to 6.0 GHz
The introduction of the latest member of the Active Head family, 9560, once again underlines our commitment
to oscilloscope calibration. With our continued focus on securing your investment, the 9560 Active Head is the
latest product to fulfill this promise, allowing current users of the 9500 to upgrade their equipment to any
9500B status and take advantage of more recent product and performance enhancements. The 9560 is able to deliver
6.0 GHz leveled sine wave and pulse edges of only 70 ps.
Unlike other oscilloscope calibrators, you’re not restricted to fixed amplitude pulses. Active Head Technology™
lets you adjust output amplitude between 4.44 mV and 3.1V, allowing you to check an oscilloscope’s amplifiers
right down to their most sensitive ranges. Whatever amplitude you choose, controlled waveshape filtering ensures
that all high-speed edges have an accurately defined energy distribution.
- Full automation provides totally hands-free oscilloscope calibration - even on today’s ultra-high performance,
multi-channel, feature rich instruments.
- Continuous upgradeability helps you protect your investment in the tools you need to manage ever changing workload demands.
- Simultaneous output on 5 channels means no more lead changing and no more complicated signal multiplexers or impedance matching networks.
- Leveled sinewaves to 6.0 GHz and edges to 70 ps provide all the performance and flexibility you need to fully calibrate
today’s and tomorrow’s high performance oscilloscopes.
- Fluke’s unique Active Head Technology™ generates calibration signals right at the oscilloscope input – now there is no doubt whether
waveform aberrations are down to connecting leads or the oscilloscope itself.
Do you need to justify the expense of a new oscilloscope calibrator? Our Oscilloscope Calibrator Return on Investment
Calculator can help you estimate how long it will take to recover the costs invested in a new calibrator. The calculator
is an easy-to-use downloadable Excel file (55 KB).
|
Contact us for more information... |