Options/Accesssories
 |
RemotEyeII
Accessories
RemotEye II is a complete Toshiba Uninterruptible Power Systems (UPS) management solution! RemotEye II is a tool designed to control and monitor Toshiba UPS remotely via Simple Network Management Protocol (SNMP) and Hypertext Transfer Protocol (HTTP/web browser) methods. In addition, when a power outage occurs, notification can be sent to the network administrators or maintenance personnel. Should a prolonged power outage occur, RemotEye II can initiate an orderly shutdown to connected servers to minimize any risk of data loss.
Other Features:
- Provides Management of UPS through Web Browser
- Provides Management of UPS through SNMPv1 and SNMPv3
- Supports Flash Upgrade through Network
- Provides Shutdown of Remote Client on LAN
- Provides Versatile Power Management Control
- Provide E-Mail Notification of UPS Status and UPS Events
- Provides Remote Control of UPS through Internet
|
 |
Remote-D
Accessories
The Remote-D is an intelligent power management system that provides power management for any combination of network equipment connected to it. Users can control the power on/off for any device connected to the Remote-D, manually or remotely, using a console or Ethernet connection. The Remote-D comes with eight power outlets, each of which can be monitored and controlled through the console or web interfaces. Users can also use the front panel to operate the power outlets.
- Protection of Electronics Equipment from Random Surges & High Amplitude Spikes
- Comprehensive Power Management via RS232 and Ethernet with Browser or SNMP
- Remote Management Individual Output Power Receptacles
- Programmable Turn On/Off based on Specific Events
- Event Notification through SNMP Trap and Email Alerts
- Detailed Data-Logging For Statistic Analysis and Diagnostics
- Double-Layer Security for Adminstrators and Users
- Optional Connectivity of Versatile Sensors via Environmental Monitoring Device
|
 |
Environmental Monitoring Device (EMD)
Accessories
The Environmental Monitoring Device (EMD) is a monitoring device that provides real time comprehensive remote monitoring of environment temperature, environment humidity and other environmental conditions via web browser, Network Management System (NMS), Java Applet, Telnet, SNMP or Hyper Terminal
Features:
- Provides Real time Monitoring of Environmental conditions
- Provides Two User Defined Dry Contacts for Additional Environmental Monitoring
- Provide Automated Events Notification of EMD Status and EMD Events via HTTP and SNMP
|
 |
Industrial Bus
Accessories
The Toshiba Industrial Bus Product, ProtoNode, is designed to provide a reliable interface between Toshiba's 1600EP Series, 4200FA Series and G8000 Series Uninterruptible Power Systems and your Building Management System. ProtoNode converts real time UPS data into the user's Building Management System protocols. ProtoNode supports SNMP, Modbus RTU, Modbus TCP, BACnet (including BACnet IP), and Metasys N2 industrial protocols. The configuration files for these protocols are available for download free from the Toshiba Industrial Bus website. ProtoNode hardware connectivity includes two DB9 (RS232 and RJ485) connectors which enable users to connect to DTE-type devices, and a RJ45 connector for network connectivity.
Features:
- Multiple Industrial Bus Protocol Includes SNMP, Modbus RTU, Modbus TCP, BACnet (including BACnet IP), and Metasys N2
- Connectivity includes DB9 and RJ45 Connectors
- Product Supports 1600EP, 4200FA & G8000 (Coming Soon on G8000MM)
|
 |
1000 Series Options
Accessories
Model UT1-BC-0125 - 1000 Series 1.0 - 1.5kVA Matching Battery Cabinet Tower
Model UT1-BR-0125 - 1000 Series 1.0 - 1.5kVA Matching Battery Cabinet Rackmount.
Model UT1-BC-0225 - 1000 Series 2.0kVA Matching Battery Cabinet Tower
Model UT1-BR-0225 - 1000 Series 2.0kVA Matching Battery Cabinet Rackmount.
Model UT1-BC-0320 - 1000 Series 3.0kVA Matching Battery Cabinet Tower
Model UT1-BR-0320 - 1000 Series 3.0kVA Matching Battery Cabinet Rackmount
All batteries cabinets include Internal Charger, DC Circuit Breaker and Anderson Style Connector Cable.
1000 Series On-Line UPS Remote Contact Card - The remote contact card is a solid state relay switch contact through a DB9 male connector. This card will be inserted to the optional slot located on the back of the 1000 Series UPS.
1000 Series On-Line UPS Frequency Conversion - Frequency Conversion software allows the UPS to output a fixed frequency. For example, if input frequency is 50Hz and load required a 60Hz, end users could program the UPS to ouput 60Hz at all time from the UPS LCD. No hardware changes required, only software upgrade on UPS. Please refer to Setup Software for detail information. |
 |
1600EP Series Options
Accessories
- UE31-6LC-50A - 1600 Ser 6.0kVA 6-50 Plug w/ 8" Inp Line Cord (3 wire)
- UE31-8LC-50A - 1600 Ser 8.0kVA 6-50 Plug w/ 8" Inp Line Cord (3 wire)
- UE3-RP-B3 - 1600 Ser 3.6kVA ~ 6.0kVA Output Receptacles Four L6-30R, Two 5-15R (Duplex)
- UE3-RP-B5 - 1600 Ser 3.6kVA ~ 6.0kVA Output Receptacles Five 5-20R (Duplex)
- UE3-RP-B7 - 1600 Ser 3.6kVA ~ 6.0kVA Output Receptacles Two L6-30R, Four 5-15R (Duplex)
- UE3-RP-C5 - 1600 Ser 8.0kVA Output Receptacles Five 5-20R (Duplex)
- UE3-RP-C7 - 1600 Ser 8.0kVA Output Receptacles Two L6-30R, Four 5-15R (Duplex)
- UE31-BC-0650 - 1600 Series 3.6kVA ~ 6.0kVA Matching Battery Cabinet - This battery cabinet provides 70 minutes of battery backup at 3.6kVA load and 50 Minutes of battery backup at 6.0kVA load. This battery cabinet includes Internal Charger, DC Circuit Breaker, Hot-Swappable Batteries and Anderson Style Connector Cable.
- UE31-BC-1825 - 1600 Series 8.0kVA ~ 18.0kVA Matching Battery Cabinet - This battery cabinet provides 75 minutes of battery backup at 8.0kVA load, 50 Minutes of battery backup at 10.0kVA load, 35 Minutes of battery backup at 14.0kVA load and 25 Minutes of battery backup at 18.0kVA load. This battery cabinet includes Internal Charger, DC Circuit Breaker, Hot-Swappable Batteries and Anderson Style Connector Cable.
|
 |
1800 Series Options
2400 VA
Panel Option 1: UG1-RP-P1 - Line Cord: L14-20P Receptacles: One L14-20R , Two 5-20P (Duplex)
Panel Option 2: UG1-RP-P2 - Line Cord: L6-30P Receptacles: Four 5-20P (Duplex)
Panel Option 3: UG1-RP-P3 - Line Cord: L6-30P Receptacles: Three L6-30R Two 5-20P (Duplex)
Panel Option 4: UG1-RP-P4 - Line Cord: L6-30P Receptacles: Three L5-30R Two 5-20P (Duplex)
Panel Option 5: UG1-RP-P5 - Line Cord: L6-30P Receptacles: Three L6-20R Two 5-20P (Duplex) |
 |
4200 Series Options
Accessories
Toshiba offers a wide range of options for the 4200 Series matching battery cabinets. Users have the options to choose from a range of different backup time at different kVA size. |
 |
G8000 Series Options
Accessories
Toshiba offers a wide range of options for the G8000 Series matching battery cabinets. Users have the options to choose from a range of different backup time at different kVA size. |
Contact us for more information... |
|
|